Data Center

The indoor air quality in data centres has become a major importance with specified standards being established to classify the airborne contaminants and biological influences that may affect any electronic hardware.

Step 1: Identify



Reactivity Measurement Kit

(Corrosion Coupon)
  • Measure Air Reactivity as per ANSI/ISA-71.04.2013
  • Qualifies & Quantifies the presence of Reactive Gases in the controlled Environment
  • Handy tool & Very Reliable method to provide Air Quality Assessment Reports
  • Can measure performance of the Chemical Filters installed
  • Utilizes constant-current coulometricmethod accordance to ASTM B 825-02 to determine the corrosion rate of the exposed environment

request info

STEP 2: ELIMINATE



DeaKleenEC/SD/SU/SP/MG

(Synthetic Fiber Pre-Filter)
  • G4, M5
  • Beverage board, Galvanized steel
  • Standard depth 22mm, 44mm and 95mm
  • Non-woven cotton synthetic blend
  • Intercept is available
  • UL certified

request info

Stand Alone Purifier/Pressurizer

Air Purification Equipment
  • Low Noise, Stand-Alone Construction
  • Low Power AC or DC fans
  • Multiple stages of both particulate and chemical filters
  • Customized design based on requirements
  • Recommended for Low PPM to PPB levels of contaminants

request info

18CS & 12CS

Cassette Modules
  • Available in Plastic construction
  • Contemporary, Low Resistance Design
  • Optimized Design for Energy Efficient Performance.
  • Available in 18” & 12” standard depths
  • Suitable to work up to 500FPM (2.54m/s)
  • Recommended for Low PPM to PPB levels of contaminants.

request info

TerraComb

Honeycomb Grid
  • Latest Technology in Chemical Filter Media
  • Very Low Pressure Drop; High Energy Saving Potential
  • Available in various specification and sizes
  • Can remove wide spectrum of Impurities
  • ULTRA LOW DUST Carry Over
  • Totally Safe & Non-Toxic Fresh (New) Media
  • Suitable for all types of installations, such as Deep Filtration Beds, Cassette & Canister Module equipment systems
  • Easy to Install & Replace

request info



MiraCel II

Mini-Pleat Type Medium High Efficiency Filter
  • F6, F7, F8, F9
  • Dual density, ultra-fine fibreglass
  • Available in Beverage board, Water resistant board
  • Standard depth 95mm
  • UL certified

request info

TerraOxi

Air Purification Media
  • Activated Alumina Based Oxidization Media
  • Utilizes Chemisorption Method to remove Target Impurities
  • Can remove wide spectrum of Impurities
  • Most suitable media for all Indoor Air Quality (IAQ) Requirements
  • Totally Safe & Non-Toxic Fresh (New) Media
  • Suitable for all types of installations, such as Deep Filtration Beds, Cassette & Canister Module equipment systems
  • Easy to Install & Replace

request info

TerraOxi Blend

Air Purification Media
  • Equal Volume Blend of JAF TerraCarb & TerraOxi
  • Activated Alumina Based Oxidization Media; Activated Carbon Based Absortpion Media
  • Can remove wide spectrum of Impurities
  • Most suitable media for all Indoor Air Quality (IAQ) Requirements
  • Totally Safe & Non-Toxic Fresh (New) Media
  • Suitable for all types of installations, such as Deep Filtration Beds, Cassette & Canister Module equipment systems
  • Easy to Install & Replace

request info


Step 3: Monitoring



Reactivity Measurement Kit

(Corrosion Coupon)
  • Measure Air Reactivity as per ANSI/ISA-71.04.2013
  • Qualifies & Quantifies the presence of Reactive Gases in the controlled Environment
  • Handy tool & Very Reliable method to provide Air Quality Assessment Reports
  • Can measure performance of the Chemical Filters installed
  • Utilizes constant-current coulometricmethod accordance to ASTM B 825-02 to determine the corrosion rate of the exposed environment

request info

Environmental Condition Monitor (ECM)

  • Corrosion rate of Copper and Silver Sensors as per ANSI/ISA-71.04.2013
  • Monitors corrosion rate, relative humidity, temperature and differential pressure
  • High sensitivity corrosion rate measurement
  • Provides both Digital and Analog outputs
  • Optional storage in on-board datalogger that is accessible with PC software

request info

Lab Services

  • Monitors media usage for a gas phase filtration system.
  • Analysis is capable to predict chemical media’s remaining life
  • Information obtained can reflect;
    • Existing system’s characteristics and effectiveness
    • Replacement cycle necessary for maximum performance.

request info
TOP